Ce Compliance Fully Undershot Spraying and Baking Cabin for Auto
1.HIGHLIGHTS
Solution: 1 Prep station, 1 Paint booth and 1 Mixing room
The automotive refinish solution comes with 1 prep station, 1 paint booth and 1 mixing room, the combination of which can suit most auto body shops' needs. Infitech can also customize the solution to meet your personalized requests.
The spray booth is with downdraft airflow, robust structure, superior lighting, high performance direct gas fired generator and easy-to-use control. It belongs to our top of line spray booth. The adjacent mixing room offers the workspace for paint mixing, and the service door in-between provides the convenience from mixing room to spray booth.
The prep station is with rear semi downdraft airflow, electric and tool cabinets on the rear wall, facilitating the operation for prepping, and electric soft curtain doors, convenient for the in and out of vehicles.
2.SPECIFICATIONS
PAINT BOOTH |
ITEMS |
SPECIFICATIONS |
Model |
IT-SUPER-L8 Paint Booth for Car Refinishing |
Design standard |
BS EN 13355: 2004+A1:2009 BS EN 60204: 2006+A1:2009 |
Internal dimensions |
8000 X 4000 X 3000mm (L X W X H) |
External dimensions |
8110 X 5760 X 4010mm (L X W X H) |
Airflow |
Full Downdraft |
Plenum (height) |
600mm |
Extraction |
Through 350mm high raised basement |
Extraction area |
32m2 |
Grids carrying capacity |
900kg/wheel |
Internal ramp |
Pneumatic ramp, 1 set |
Entrance door |
3400x3250mm (WxH), 1 set |
Service door |
840x2250mm(WxH), 2 sets |
Walls |
60mm rock wool walls, 1.0mm substrate |
Ceiling lights (LED) |
10 sets, each 6 X 18W, 1,080W total |
Sidewall lights (LED) |
14 sets, each 3 X 12W, 504W total |
Brightness |
>1,500LUX |
Filters |
Bag filter, high efficiency ceiling filter, floor filter, exhaust filter |
Intake/Exhaust unit |
Direct-type turbine fan, 2x11KW, SIEMENS motor |
Air volume |
35,000m3/h |
Empty loaded air speed |
0.30m/s |
Heats |
Direct gas fired heating system, ECLIPSE burner |
Maximum working temperature |
80ºC |
Controls |
CE standard control box |
Inverter |
SCHNEIDER inverter |
Stack light |
Yes |
Rated power |
28KW |
PREP STATION |
ITEMS |
SPECIFICATIONS |
Model |
Car Prep Station |
Design standard |
BS EN 13355: 2004 + A1: 2009
BS EN 60204: 2006 + A1: 2009 |
Internal dimensions |
6850×4000×3350mm (L×W×H) |
External dimensions |
8110×4075×4010mm (L×W×H) |
Rear wall |
50mm rock wool panels |
Plenum |
With plenum, 600mm(H) |
Exhaust plenum chambers |
4000*660*800mm |
Filter areas |
3.2m2 |
Front door |
3700x3000mm, 1 set, electric soft curtain door |
Divider door |
5800x3000mm, 1 set, electric soft curtain door |
Ceiling lighting |
8 sets, each 4 X 18W, 576W total |
Brightness |
> 700Lux |
Exhaust system |
1×5.5KW, 970RPM, 380V, 50HZ, SIEMENS motor |
Air volume |
18,000m3/h, 650pa |
Filters |
High efficiency ceiling filter, pleated andreae filters + fiberglass filter, exhaust filter |
Controls |
Soft start, emergency stop switch, lighting, failure indication |
Electrical & Tool cabinets |
Yes. |
Special item |
Rated power: 10KW |
3.DETAILS
AIRFLOW & BOOTH STRUCTURE (PAINT BOOTH)
1.600mm plenum
The plenum comes with diffuser unit, providing the assistance to reduce air speed before air flows to the plenum, which helps achieve even air distribution.
2.Vertical walls.
3.Raised basement
The air flows vertically from the plenum to the workspace, and extracted through raised basement. In the basement, there is also diffuser to for adjusting airflow speed, so the air can be balanced from one end to the other end.
DOORS & LIGHTS
- 2+2 structure entry door: 3400x3250mm
- Service door with full size tempered glass observation window
- Inclined ceiling and horizontal sidewall lights
AIR INTAKE AND EXHAUST UNIT
- Non-spark fan & SIEMENS motor
- Cycle damper (for spraying and baking phase)
- Direct gas fired heating unit, Eclipse direct fired burner
- 97% efficiency
- Accurate temperature control
CONTROL
- Basic functions: spraying, heating spraying, flash, baking, cooling
- Safety functions: emergency stop, over-heat alarm, failure alarm, fans interlock with heating system
- SCHNEIDER inverter control
UPGRADE
- Traditional control panel with manual buttons
- Automatic pressure adjustment
CAR PREP STATION
- 600mm plenum
- Flat ceiling lighting fixtures
- Exhaust fan unit, 1*5.5kw
- Exhaust plenum chambers at the back
- Electrical and tool cabinets on the rear wall
- Electric soft curtain door in the front and on the side
CONTROL BOX AND TOOL BOX (FOR PREP STATION)
Arrangement: on the rear wall
OPTION
- The servo of central dust extraction unit can be integrated in the control panel
ELECTRIC SOFT CURTAIN DOOR
FAQ
Q: I want to visit your factory. Where is your office and factory located?
A: We are located in Guangzhou, 15 minutes' drive from the airport. Welcome to visit us.
Q: Do you have spray booth sample to show me when I visit you?
A: Yes, we have show room here at the factory. Meanwhile, we can also show you spray booth operating at our customers' workshops nearby so you can better learn our products.
Q: What if I meet problems when installing your spray booth?
A: Firstly, report the problems to us. We will reply in time and propose the solution to get problems solved. We are always responsible for the products and solution that we provide.
Q: What is the MOQ of your spray booth?
A: 1 set.
Q: How long does it take for me to receive the spray booth?
A: For standard spray booth, the production lead time is 35 days. The shipping is usually 6 weeks after EXW depending on the destination port.
Q: How long does it take to install the spray booth? And how many people I need?
A: For a standard spray booth, usually it can be installed within 10 working days by 3-4 people (including 1 professional electrician).